steam boiler which supplies steam to process system at specified pressure

Product thermal capacity: 4-35 t/h
Working pressure: 1.0-2.5 MPA
Outlet temperature:: 184-350 ℃
Available fuel: Bituminous coal, lean coal, anthracite
Available industries: Heating, chemical, food, tobacco, textile, print and dyeing, feed, medicine, building materials, wine, hospital

Steam boiler system - Spirax Sarco Limit

1990-7-3 · I claim: 1. A steam boiler system which includes a steam boiler (10), a feed water inlet (12) to the boiler for boiler feed water supply, a steam outlet (14) from the boiler, a blowdown outlet (16) from the boiler, and valve means adjustable to provide a blowdown rate which is a porportion of the feed rate of the boiler feed water characterised by means comprising an impurity sensor (40) to

Get A Quote

Flash Steam | Spirax Sar

Figure 14.6.6 shows an application where the flash steam system is kept at a specified constant pressure by steam fed from a reducing valve. This ensures a reliable source of steam to the low pressure system if there is a lack of flash steam to meet the load.

Get A Quote

HRSG back pressure - Boiler and Pressure Vesse

If the steam cycle is a reheat cycle and the plant has a steam to reheater bypass system, then the steam will pass from the reheater into the IP turbine via the intercept valve.If the HP bypass discharges directly to the condenser, then the condenser pressure will increase and eventually trip the plant if the condenser backpressure exceeds trip

Get A Quote

Steam Sterilization | Disinfection amp; Sterilizatio

The basic principle of steam sterilization, as accomplished in an autoclave, is to expose each item to direct steam contact at the required temperature and pressure for the specified time. Thus, there are four parameters of steam sterilization: steam, pressure, temperature, and time.

Get A Quote

Characteristics of boiler feedwater - Lennte

Composition that boiler feedwater should have depending on boiler working pressure. Water Treatment Solutions to 1500 mg/l in fresh water supplies. Since water impurities cause boiler problems, careful consideration must be given to the quality of the water used for generating steam. The composition of boiler feed water must be such that

Get A Quote

Steam Sterilization | Disinfection amp; Sterilizatio

The basic principle of steam sterilization, as accomplished in an autoclave, is to expose each item to direct steam contact at the required temperature and pressure for the specified time. Thus, there are four parameters of steam sterilization: steam, pressure, temperature, and time.

Get A Quote

Specification 36. Heating, hot and cold water, steam an

2012-12-10 · 2.9.1 Steam Boiler Systems 2.9.2 Hot Water Boiler Systems 2.9.3 General Requirements Protection Controls Pressure Gauges Steam Traps Strainers for Hot Water Heating Systems Hot and Cold Water Mixing Valves and Fittings Table 10A Minimum Thickness of Insulation for Cold Water Supplies to Prevent Condensation on a High Emissivity Outer

Get A Quote

UNIVERSAL Steam Boiler UL-S, UL-SX by Bosc

UNIVERSAL Steam Boiler UL-S, UL-SX by Bosch Industriekessel The flame tube, internal water-flushed rear flue gas reversing chamber, first smoke tube and second smoke tube are all arranged for optimum flow within the cylindrical pressure vessel.

Get A Quote

Steam System Network Synthesis Using Proces

Steam boilers are used to generate steam in order to meet the duty requirements of cold process streams. The most common heat exchanger network layout associated with the boiler is a completely

Get A Quote

Steam Traps amp; Gauges - Engineered Products at BP

Steam traps are generally used in drip, process and tracing applications, and come in a variety of sizes and types to effectively handle various operating conditions. Proper selection of a steam trap is mainly dependent on the application type, condensate load and operating pressure.

Get A Quote

Technical Data A Comparison: Rev.500 Thermal Fluid vs

2017-8-19 · in most process operations, steam systems would have to operate at exceptionally high pressures. At 600˚F for example, a saturated steam system develops about 1600 psi. Even at 400˚F, the pressure is still high — about 235 psi. In contrast, most thermal fluid systems are vented to atmosphere. Pump discharge pressure is just

Get A Quote
Contact us
Tel

0086-510-68530066

Chat online

Online message


Gas-fired(oil-fired) boilers
Coal-fired boilers
Biomass-fired boilers
Thermal oil heaters
Hot water:0.7-14 MW
14.1-21 MW
21.1-29 MW
29.1-75 MW
Steam :  1-10 t/h
11-20 t/h
21-90 t/h
91-140 t/h